Switchmode Voltage Converter GEN II Maxi 24-12 VDC 25Amps
SVC241225G2
Quick Overview
“With digital over analogue topology the GEN II range allows the installer/operator to control and monitor various functions”
Electrical
Output Voltage (Converter Mode) | 12 - 14V |
---|---|
Output Voltage (Charger Mode) | Two stage battery charging mode with boost voltage of 14.4V and float of 13.6V |
Input Voltage | 20 - 33VDC (will dip to 17V) |
Constant Rating | 25 Amps (rated @ 40°C) |
Intermittent Rating | 25% rating over the continuous rating at a maximum of 50% duty cycle for 10 minutes |
Momentary Rating | Peak at greater than 25% of continuous rating for 10 seconds |
Galvanic Insolation | No |
External Alarm Output | An external signal for remote monitoring of both the pre-emptive and shutdown alarms |
Minor Power Output | A permanent low current output used in conjunction with remote isolation i.e. to power a clock, etc. |
Remote Switching Input | Used to isolate the 24VDC from the 12VDC with a simple, low current, control switch i.e. toggle switch |
Physical
Input/Output Terminals | High current proprietary terminals with combination M5 fasteners |
---|---|
Control/Monitoring Terminal | Customized 3 gang Euro block |
Construction | Manufactured using corrosion resistant materials throughout, including anodised 6063 aluminium, ABS/ PC plastics and stainless steel hardware. No ferrous materials are used and all PCB assemblies feature conformal coating (tropicalisation). |
Operating Temp | -25°C to + 50°C |
Operating Humidity | Ideally less than 90% |
Dimensions (overall) | 170mmL x 110mmW x 55mmH |
Weight (nominal) | 750 Grams |
Protection
Input Under Voltage | Warning and shutdown |
---|---|
Output Overload | Warning and shutdown |
Over Temperature | Warning and shutdown |
The GEN II range of SVC Maxi Series Voltage Converters as they are known, are designed on the solid foundation of the original product with a host of new features and benefits. With digital over analogue topology the GEN II range allows the installer/operator to control and monitor various functions and provides valuable feedback on the status of the connected load. The GEN II is more compact due to multi-speed fan cooling and as a result no longer relies on convection for cooling.
The GEN II Maxi Series models are designed for high performance installations where a 12VDC source is required in a 24VDC application. The common negative SVC version provides maximum efficiency at a cost effective price.